| Universal input 100 to 240 VAC Single output Over power protection 100% Hi-Pot tested 100% cycling burnt-in. |
||
| Load regulation: 5% Maximum power: 48W for convection cooled Hold up time: 16ms at full load, 120 VAC Efficiency: 80~84% typical at full load Transient response: main output 50-100% load and output regulation meet spec. |
||
| Input voltage: 90 to 264 VAC Input frequency: 47 to 63 Hz Input current: 1.2A max at 90 VAC Inrush current: 100 A max. for two cycles or less Protection: 2 A fuse on board |
||
| Topology: FLYBACK Dielectric strength test: 3K VAC primary to secondary Insulation resistance: 50M Ohm @ 500 VDC primary to secondary Leakage current: Less than 0.25 / 3.5 mA @ 240 VAC 50 Hz MTBF: 50,000 hrs min. at full load and 25°C |
||
| Conducted / radiated emissions: Meet FCC Part 15 CLASS B, CISPR 22 CLASS B |
||
| Operating temperature, full load, no derating:0~40°C Non-operating: -20~85°C Relative humidity non-condensing: 0~95% Altitude: Sea level up to 25,000 feet Cooling: Convection cooled Shock: Per MIL-STD-810C 516 Part V Vibration: 10 to 500 Hz, 15 mins / cycle / axis |
||