| Universal input 100 to 240 VAC Single output Overload protection 100% Hi-Pot tested 100% cycling burnt-in. |
||
| Line regulation: 0.20% Load regulation: 5% Maximum power: 60W for convection cooled Hold up time: 20ms at full load, 120 VAC Efficiency: 65% typical at full load, varies with distribution of loads among outputs Transient response: main output 50-100% load 10% max. dev. 10 ms recovery Overvoltage protection: All output Short circuit protection: All output Overcurrent protection: All output |
||
| Input voltage: 90 to 264 VAC Input frequency: 47 to 63 Hz Input current: 1.4A max at 90 VAC Inrush current: 100 A max. for two cycles or less Protection: 2 A fuse on board Configuration: IEC 60320 C8, C6 |
||
| Topology: FLYBACK Dielectric strength test: 3K VAC primary to secondary Insulation resistance: 50M Ohm @ 500 VDC primary to secondary Leakage current: less than 0.25 mA @ 240 VAC 50 Hz MTBF: 50,000 hrs min. at full load and 25¢XC |
||
| Conducted / radiated emissions: Meet FCC Part 15 CLASS B, CISPR 22 CLASS B |
||
| Operating temperature, full load, no derating:0~40¢XC Non-operating: -20~85¢XC Relative humidity non-condensing: 0~95% Altitude: Sea level up to 25,000 feet Cooling: Convection cooled Shock: Per MIL-STD-810C 516 Part V Vibration: 10 to 500 Hz, 15 mins / cycle / axis |
||